High Precision Ultrasonic Thickness Gauge ITI-1600

Ultrasonic Thickness Gauges are designed to improve safety and ensure the reliability of material subject to corrosion or erosion.

 

Corrosion gauges with dual-element transducers are the primary inspection tool used to measure the remaining walls of components such as pipelines, pressure vessels, storage tanks, and numerous other applications.

 

Precision gauges use single-element transducers to provide the thinnest range and highest degree of accuracy possible. Common applications include metals and a variety of non-metals (i.e. glass, ceramic, plastic, etc.)

 

Specifications:

Measuring Range

0.65 mm – 400mm (upto 500mm) (in steel)

Sound Velocity

1000~9999 m/s

Resolution

0.01mm/0.1mm or 0.001/0.01”  selectable

Units

mm/inch (selectable)

Memory

Upto 2000 Groups (up to 99 Values for each file)

Accuracy

± ( 0.5%Thickness+0.04 ) mm

Alarm

preset upper and lower limit

Work Voltage

3V (2 AA alkaline batteries)

Work mode

Single point and scan

Interface port

USB

Dimensions

136 x 72 x 20mm

Weight

177 g

Display

3.5 digit LCD with  EL backlight

Continuous Working Period

280  hours (with  EL backlight off)

 

Standard Delivery: Main Unit, TWO test Probes, Data Cable, Software, Coupling oil, Battery, Operation Manual, Carrying case.

Ultrasonic Thickness Gauge A&B Scan Thru-Paint & Coatings Thickness Gauge ITI-218DL

Product Description:

PG-AB Series Color Screen with A/B-Scan Ultrasonic Thickness Gauge Professional in Solving Various Difficult Thickness Measurement

 

Features:
2.4” color OLED, 320 X 240 pixels, contrast 10,000:1

 

Live Color A-Scan

Users could directly see the color waveform of the ultrasonic sound (or A-scan) on the screen, which is quite important for the occasions that we need to check the correctness of the testing results. Many cases will cause wrong testing results or even no readings. We could find the causes easily through the A-scan. Adjust the three parameters of GAIN, BLACKING, GATE, and then we will get the right readings.

 

Live Color B-Scan

ITI-218DL series thickness gauge has a time-based B-scan function. Move the probe along the workpiece surface, then the cross-sectional profile of the workpiece display, use for observe the underside contour of the workpiece. It could automatically capture a minimum value of the B-scan image, and indicate the position of the minimum by a red triangle. You can see any point thickness value of the B-scan image by moving the pointer.

 

Through Coating Function No longer need to waste time to remove the coating

Now we also have this widely acclaimed function. It’s realized by measuring the two continuous bottom surface of the substrate. This mode also has more advantages:

Exempt Zero Calibration

High Stability, the measuring value is not influenced by the probe pressure, the coupling layer thickness and the surface dust of the workpiece.

● Zero Drift

 

More Practical Function: 

 

Difference/Reduction Rate: Difference mode displays the difference between the actual value and the normal value. Reduction rate calculates and shows the percentage of the thickness reduction when the material becomes thin. A typical application is to measure the metal material which is due to bending and becomes thin.

 

Max. /Min. Capture: In this mode, the current thickness, minimum thickness and the maximum thickness will be shown on the screen at the same time.

 

Alarm Mode: Dynamic change in the colour of thickness readings when alarming.

 

Update Rate: Selectable 4Hz, 8hz and 16Hz. 4Hz for ordinary applications, when you need a quick scan, such as high-temperature measurement, you can choose a higher update frequency.

 

Multi-Languages Available: Chinese, English, Japanese, French, German.

 

Standard PG510 Probe: 

The probe is the heart of the instrument. PG510 probe uses a high-performance piezoelectric ceramic chip, with an integrated metal die-casting shell, practical design of probe and cable separated, regardless of costs to create high quality.

Coating Thickness Gauge ITI-3000

High Accuracy And Wide Range Coating Thickness Gauge With Separated Probe ITI-3000

 

Product Description:

The measuring range of this coating thickness gauge is up to 5000um. It is used for non-destructive coating thickness measurement of nonmagnetic coatings on steel and insulating coatings on non-ferrous metals. It has with separated external probe and can be replaced easily.

High accuracy and stability, wide measuring range
With separated probe and can be replaced easily
128X128 dot matrix LCD Display and menu interface
LCD shows mean, maximum, minimum and standard deviation
User can set alarm limit and red backlight indication
Readings can be stored, recalled and deleted
Easy to do zero calibration and multi-point calibration supported
Connect with PC via USB to download readings
Multiple languages supported
Up to 5 measurement groups supported
● Detect the type of substrates automatically

 

Specifications: –

 

Model

ITI-3000

Probe

F-Probe & N-Probe

Measuring Principle

Magnetic induction & Eddy Currents

Measuring Range

Up to 10000 um

Accuracy

± (1%+5 um)

Resolution

0~99.9um(0.1um), others(1um)

Calibration

One point to four points calibration, zero point calibration

Data Group

One direct group(readings not be stored in memory)

Four general groups (readings will be stored automatically)

NOTE: each group have individual statistics, alarm limit settings,

and calibration

Statistics

No. of readings, mean, minimum, maximum and standard deviation

Units

um, mm, mil

Alarm

Users can set the high/ low alarm limit; Alarm icon displayed on the LCD when over the limit

Minimum Curvature
Radius Convex

1.5 mm

Minimum Curvature
Radius Concave

25 mm

Minimum Measuring
Area

Diameter 6 mm

Minimum Thickness
Of Substrate

F-Probe: 0.5 mm(0.02″); N-Probe: 0.3 mm(0.012″)

Computer Interface

Download data via USB

Power Supply

Three 1.5 V AAA battery

Operation Environment

Temperature: – 10 to 50

Storage Environment

Temperature: – 10 to 60°C (-4 to 158°F)

Standard
Certification

CE, ROHS, ISO 2178, 2360, GB/T 4956-2003, 4957-2003

Dimensions

158mmX68mmX34mm/ 170g/ ABS

 

Standard Delivery: Main Unit, TWO test Probes, Data Cable, Software, Coupling Oil, Battery, Operation Manual, Carrying case.

Submit Your Enquiry

    All Brand Names and Logo’s Belongs To Their Respective Owners.